Glass-Fiber-Reinforced Thermoset Resin Corrosion-Resistant. Tanks. View on Information Provider website {{ linkText }}. Abbreviation. ASTM D – ASTM D(). Standard Specification for Contact-Molded Glass-Fiber- Reinforced Thermoset Resin Corrosion-Resistant Tanks. ASTM D Standard Specification for Contact-Molded Glass-Fiber- Reinforced Thermoset Resin Corrosion-Resistant Tanks.

| Author: | Sazahn Akilkree |
| Country: | Luxembourg |
| Language: | English (Spanish) |
| Genre: | Relationship |
| Published (Last): | 20 January 2007 |
| Pages: | 358 |
| PDF File Size: | 14.44 Mb |
| ePub File Size: | 3.39 Mb |
| ISBN: | 685-4-91351-592-2 |
| Downloads: | 41461 |
| Price: | Free* [*Free Regsitration Required] |
| Uploader: | Vogami |
Resources & News
This specification does 4907 cover the design of vessels intended for pressure above hydrostatic, vacuum conditions, except as classified herein, or vessels intended for use with liquids heated above their flash points. Design Tanks stores resins in a climate-controlled storage area to eliminate production variances related to temperature changes.
Certified fabricators can provide an RTP-1 stamp on qualifying tanks. Included are requirements for materials, properties, design, construction, dimensions, tolerances, workmanship, and appearance. This standard does not purport to address all of the safety concerns, if any, associated with its use.
Link to Active This link will always route to the current Active version of the standard. Materials shall be tested and the individual grades shall conform to specified values of design requirements such as straight ast, external pressure, top head, bottom head, open-top tanks, joints, fittings, hold-down lugs, and lifting lugs; laminate construction requirements such as structural tank, joints, and fittings and accessories; satm other requirements such as physical properties, chemical resistance of resin, glass content, tensile strength, flexural properties and degree of cure.
The tanks are classified as type I and II according to the operating pressure or vacuum levels, and the safety factor required for external pressure. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.
For example, RTP-1 does not require a fabricator to keep materials in an environmentally controlled storage area prior to manufacturing.
The Design Tanks Difference: Exceeding The Standards | Design Tanks
Design Tanks complies atsm the design strength requirements of ASTM Dutilizing a rigorous in-line and end-of-line quality control process plus testing of all resins and incoming materials. All tanks are designed by an in-house professional engineer for design purposes, including a detailed QC program and a QC lab to keep tank production according to RTP-1 standards. The tanks are further classified as grade 1 and 2 according c the generic types of thermoset resin. Historical Version s – view previous versions of standard.
Includes requirements for materials, properties, design, construction, dimension, tolerance, workmanship, and appearance. The values given in parentheses are provided for information purposes only.
As a custom manufacturer specializing in meeting the unique needs of our customers, our exposure to these different standards is much higher than for the manufacturer that produces a cookie cutter tank.
While Design Tanks has elected not to seek certification at this time, we meet and exceed many of the RTP-1 standards without the additional costs associated with certification.
We build a heavier, more robust tank that always exceeds the standard for wall thickness. The reinforcement should be a chopped-strand mat, a sstm biaxial or unidirectal fabric, a woven roving, or a surface mat.
This specification covers cylindrical tanks fabricated by contact molding for above-ground vertical installation, to contain aggressive chemicals at essentially atmospheric pressure, and made of a commercial-grade polyester or vinyl ester, resin.
The three predominant standards today that relate to fiberglass tanks and vessels are: It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.
Just two of the many ways Design Tanks rises above the fray without additional costs to our customers! The result is a quality product with a very low incidence of tank failure.
It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of 4907 limitations dd to use. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract asmt accurate, complete or up to date. What are Design Tanks manufacturing standards? Work Item s – proposed revisions of this standard. There is no known ISO equivalent to this standard.
The resin used shall be a commercial grade, corrosion-resistant thermoset. ASME RTP-1 As a custom manufacturer specializing in meeting the unique needs of our customers, our exposure to these different standards is much higher than for the manufacturer that produces a cookie cutter tank.
The customer receives a tank that exceeds the standard! This abstract is a brief summary of the referenced standard. Applies to manufacturing standards for Design Tanks contact-molded small- and medium-sized tanks. The dimensions and tolerances, as well as the workmanship, finish and appearance are also detailed.

The Design Tanks Difference: