within 72 hours in accordance with ASTM E “Standard Test Method for specification compliance in ASTM E “Standard Practice for Using. industry references The American Society for Testing Materials (ASTM) Standard. E, “Practice for Using Significant Digits in Test Data to Determine. ASME中国制造-ASTM E (原文)_化学_自然科学_专业资料。Designation: E29? 13 An American National Standard Standard Practice for.

| Author: | Shakakasa Vudozahn |
| Country: | Finland |
| Language: | English (Spanish) |
| Genre: | Sex |
| Published (Last): | 5 November 2015 |
| Pages: | 198 |
| PDF File Size: | 19.39 Mb |
| ePub File Size: | 17.80 Mb |
| ISBN: | 654-9-71192-254-5 |
| Downloads: | 12543 |
| Price: | Free* [*Free Regsitration Required] |
| Uploader: | Tojasar |
Rounding this value to the nearest whole number gives a value of 4, based on the information in 6. The conversion constant, An alternative statement of the suggested rule is: For example, a modulus strength, stated as Pa, may have as few as two or as many as six signi?
Historical Version s – view previous versions of standard.
The choice of method depends upon the current practice of the particular branch of industry or technology concerned, and should therefore be speci? Guidelines for Retaining Signi? The rounded value should then be compared with the speci? Dimensional quantities in zstm practice are presented only as illustrations of calculation methods.
Excel: Round 0.5 towards Even Per ASTM-E29
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? That is, the rounding unit for the speci? This abstract is a brief summary of the referenced standard.
wstm Two commonly accepted methods of rounding data, identified as the absolute method and the rounding method are described. ASTM Manual 7 provides methods for reporting x? Write down the standard deviation.
Current edition approved Aetm. The following applies to speci? When 12 is divided by 2, the resulting number, 6is the rounded value of 6 Multiplying 4 by 0.

Permission rights to photocopy the standard may also be secured from the ASTM website www. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but e299 not provided as part of the standard.
Under these conditions, the speci? Round test results to the place of the? The average and standard deviation, unrounded, are x? The examples are not binding on products or test methods treated.
Excel: Round towards Even Per ASTM-E29 – Excel Articles
The following guidelines are intended to preserve the data for statistical summaries. The rounding interval for test results should not be greater than 0. When the measuring device has a vernier scale, the last digit recorded is the one from the vernier.
Conformance or nonconformance with the speci? It is informational only and not an official part of the standard; the full text of the aastm itself must be referred to for its use and application.
Reporting s to within 0. If two choices are possible, as when the digits dropped are exactly a 5 or a 5 followed only by zeros, choose that ending w29 an even digit. Last previous edition approved in as E29 — ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
In the applications of this practice to a speci? Link to Active This link will always route to the current Active version of the standard.
ASTM E29 – 13
Historical Version s – view previous versions of standard Work D29 s – proposed revisions of this standard Translated Version s: For example, the numbers It should not be inferred that a measurement value is precise to the number of signi?
Dimensional quantities in the practice are presented only as illustrations of calculation methods. This will be referred to as the absolute method, which is discussed in Section 5.
