Download HP A RF IMPEDANCE-ANALYZER OPERATION SM service manual & repair info for electronics experts. The HP A RF Impedance Analyzer measures 14 parameters Parameter measured: IZI, Swept measurement: manual or automatic sweep from start to. Agilent A Test Fixture. Operation and Service Manual. Third Edition. Agilent Part No. February Printed in Japan.

Author: Mikara Akihn
Country: Guinea
Language: English (Spanish)
Genre: Spiritual
Published (Last): 12 February 2008
Pages: 336
PDF File Size: 4.86 Mb
ePub File Size: 16.97 Mb
ISBN: 906-3-33473-981-7
Downloads: 75170
Price: Free* [*Free Regsitration Required]
Uploader: Digami

I have worked with the A and, as I recall, the commands are nothing like any other instrument I have seen.

IIRC, the sweep parameters were something like this: Would you mind posting the code you used on the A? When I gave it a try, though, it worked fine.

4191A RF IMPEDANCE ANL

Message 2 of 6. Accepted by topic author Matt C. In the code above, MHz is an arbitrary frequency. Message 6 of 6. Message 4 of 6.

Sorry, that last line of code there is supposed to read: Matt – you’re right, the commands for the A are completely different from the – probably because of its age.

  GUIDA FUORISALONE 2011 PDF

Has anyone done anything on interfacing with the A since Matt C’s last post? The forums emoticons took over for a bit there. Message 3 of 6. Message 5 of 6. Good luck with it I think the would probably take the old commands, but the ALSO has new commands.

HP A for Sale|Impedance Analyzers|Impedance Measurement Products|Test Equipment Center

It’s 84MB, so I hope you have a fast link. Most Active Software Boards: If not, what hp419a creating a driver for it entail? You really need the manual. I went through the manual before, but when I saw their GPIB section, the strings were so convoluted and so unlike anything I’ve ever seen before that I assumed it was referring to something different.

Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type. In particular, after setting up and initiating the instrument, I am initiating the measurement and reading it as follows: Thanks for your help guys.

  LIFAFA SEDEK PDF

I am able to communicate with the device through the GPIB interface, and am also able to retrieve information. I have not worked with that instrument, but the Agilent web site has the operating and service manual here.

Message 1 of 6.

Guess you never know until you try! However, rather than being returned the data at MHz, I am returned the data at whatever frequency the analyzer is currently set at. In particular, after hp411a up and initiating the instrument, I am initiating the measurement and reading it as follows:. I suspect that this difference might be causing my problems.

Should I be looking at doing it with LabView or something else?